Gamma-H2AX-Based Dose Estimation for Whole and Partial Body Radiation Exposure
2011

Estimating Radiation Exposure Using γ-H2AX Analysis

Sample size: 21 publication 10 minutes Evidence: high

Author Information

Author(s): Horn Simon, Barnard Stephen, Rothkamm Kai

Primary Institution: Health Protection Agency Centre for Radiation, Chemical and Environmental Hazards, Chilton, Oxfordshire, United Kingdom

Hypothesis

Can γ-H2AX and 53BP1 serve as effective biomarkers for estimating whole and partial body radiation exposure?

Conclusion

The study demonstrates that γ-H2AX analysis can accurately assess whole body doses and help determine partial body doses in cases of radiation exposure.

Supporting Evidence

  • γ-H2AX and 53BP1 foci were linearly induced by acute X-ray doses.
  • Mean foci counts per cell were similar across samples except at high doses.
  • γ-H2AX intensity increased linearly with dose in lymphocytes exposed to X-rays.

Takeaway

Scientists found a way to quickly check how much radiation someone got by looking at special markers in their blood cells.

Methodology

The study used ex vivo irradiated blood lymphocytes and compared γ-H2AX immunofluorescence microscopy and flow cytometry for dose estimation.

Potential Biases

Potential biases may arise from individual variations in response to radiation exposure.

Limitations

The study primarily focused on ex vivo conditions and may not fully represent in vivo responses.

Participant Demographics

21 healthy donors, aged 24–65, including 11 males and 10 females.

Statistical Information

P-Value

p=0.015

Statistical Significance

p<0.05

Digital Object Identifier (DOI)

10.1371/journal.pone.0025113

Want to read the original?

Access the complete publication on the publisher's website

View Original Publication